HTE Concrete Floor
Product Overview
Hydrothane Series H-5000
HTE Concrete Floor is a 2K waterborne polyurethane coating that offers durability and protection to concrete flooring.
Download Data Sheet
Benefits
HTE Concrete Floor offers superior durability to concrete substrates. With excellent resistance to chemicals and abrasion, it is a reliable interior coating for high wear applications.
Features
- Excellent hardness
- Excellent impact resistance
- Excellent mar and abrasion resistance
- Excellent linear flexibility
- Low VOC
Finish
- Available in: Gloss
- Color: Any
Spread Rate
- Theoretical Coverage: 802 sq. ft. per gallon @ 1 mil
- Recommended Coverage: 534 sq. ft. per gallon @ 1.5 mil
Substrates
- Concrete
Specifications
- Binder Type: Urethane
- Volume Solids: 50 ± 2% *
- Weight Solids: 54 ± 2% *
- Weight per Gallon: 8.9 lb
- Flash Point: 320ºF / 160ºC
- VOC, Material: 84 g/L
- VOC, Coating: 146 g/L
- Shelf Life: 12 months, unopened
- Pot Life: 45 - 60 minutes **
* varies by color, ** varies with temp and RH
Surface Preparation
- Concrete: Sweep the area to be coated, scrub the area with water and a push broom, and use a concrete cleaner to remove oil and grease. Rinse the area with water and apply an etching additive.
Coating Preparation
Mix Part A, scraping the sides and bottom of the container, thoroughly before measuring out the correct volume. With Part A measured out and constantly mixing, measure Part B and slowly pour into Part A. Part A and Part B must be thoroughly mixed before thinning the coating to the desired viscosity with water and applying to the substrate.
- Tinted: 4 Parts A to 1 Part B by volume
- 1 Quart: 6.4 fl oz Part B to 25.6 fl oz Part A
- 1 Gallon: 25.6 fl oz Part B to 102.4 fl oz Part A
- Clear: 3 Parts A to 1 Part B by volume
- 1 Quart: 8.0 fl oz Part B to 24.0 fl oz Part A
- 1 Gallon: 32 fl oz Part B to 96 fl oz Part A
Performance Data
No performace data available
Application Methods
With the surface and coating properly prepared, follow the below recommendations.
Add deionized water to reach the correct viscosity level. For best results, filter the coating through a fine mesh cone strainer.
Temperature should be above 60ºF and relative humidity should be above 20% at the time of application.
- Spraying: Apply a tack coat followed by a medium wet coat over the surface. Apply with an HVLP spray gun with tip size of 1.8-2.0 mm and air pressure of 25-40 psi. Nozzle size, air pressure, and viscosity are all important parameters for proper application, flow, and leveling of the coating.
- Brushing/Rolling: Apply two coats with an appropriate brush or paint roller.
Dry Times
HTE Concrete Floor can be air dried. Applying air via fans or blowers will shorten dry time.
Cure Conditions:
75ºF / 24ºC @ 50% RH
75ºF / 24ºC & XXX cfm @ 50% RH
Recoat:
TBD
TBD
Dry to Handle:
TBD
TBD
Clean-Up
While coating is wet, water may be used for cleaning. After the
coating dries, solvents may be required for clean up.