HTE Concrete Floor

Product Overview

Hydrothane Series H-5000

HTE Concrete Floor is a 2K waterborne polyurethane coating that offers durability and protection to concrete flooring.
Download Data Sheet

Benefits

HTE Concrete Floor offers superior durability to concrete substrates. With excellent resistance to chemicals and abrasion, it is a reliable interior coating for high wear applications.

Features

  • Excellent hardness
  • Excellent impact resistance
  • Excellent mar and abrasion resistance
  • Excellent linear flexibility
  • Low VOC

Finish

  • Available in: Gloss
  • Color: Any

Spread Rate

  • Theoretical Coverage: 802 sq. ft. per gallon @ 1 mil
  • Recommended Coverage: 534 sq. ft. per gallon @ 1.5 mil

Substrates

  • Concrete

Specifications

  • Binder Type: Urethane
  • Volume Solids: 50 ± 2% *
  • Weight Solids: 54 ± 2% *
  • Weight per Gallon: 8.9 lb
  • Flash Point: 320ºF / 160ºC
  • VOC, Material: 84 g/L
  • VOC, Coating: 146 g/L
  • Shelf Life: 12 months, unopened
  • Pot Life: 45 - 60 minutes **
* varies by color, ** varies with temp and RH

Surface Preparation

  • Concrete: Sweep the area to be coated, scrub the area with water and a push broom, and use a concrete cleaner to remove oil and grease. Rinse the area with water and apply an etching additive.

Coating Preparation

Mix Part A, scraping the sides and bottom of the container, thoroughly before measuring out the correct volume. With Part A measured out and constantly mixing, measure Part B and slowly pour into Part A. Part A and Part B must be thoroughly mixed before thinning the coating to the desired viscosity with water and applying to the substrate.
  • Tinted: 4 Parts A to 1 Part B by volume
    • 1 Quart: 6.4 fl oz Part B to 25.6 fl oz Part A
    • 1 Gallon: 25.6 fl oz Part B to 102.4 fl oz Part A
  • Clear: 3 Parts A to 1 Part B by volume
    • 1 Quart: 8.0 fl oz Part B to 24.0 fl oz Part A
    • 1 Gallon: 32 fl oz Part B to 96 fl oz Part A

Performance Data

No performace data available

Application Methods

With the surface and coating properly prepared, follow the below recommendations.

Add deionized water to reach the correct viscosity level. For best results, filter the coating through a fine mesh cone strainer.

Temperature should be above 60ºF and relative humidity should be above 20% at the time of application.

  • Spraying: Apply a tack coat followed by a medium wet coat over the surface. Apply with an HVLP spray gun with tip size of 1.8-2.0 mm and air pressure of 25-40 psi. Nozzle size, air pressure, and viscosity are all important parameters for proper application, flow, and leveling of the coating.
  • Brushing/Rolling: Apply two coats with an appropriate brush or paint roller.

Dry Times

HTE Concrete Floor can be air dried. Applying air via fans or blowers will shorten dry time.
Cure Conditi­ons:
75ºF / 24ºC @ 50% RH
75ºF / 24ºC & XXX cfm @ 50% RH
Recoat:
TBD
TBD
Dry to Handle:
TBD
TBD

Clean-Up

While coating is wet, water may be used for cleaning. After the coating dries, solvents may be required for clean up.